Product Center
-
Smart Occupational Therapy
-
Electrotherapy
-
Sport Therapy
-
Rehab Series
-
Cold and Heat Therapy
-
Gait Training Device
-
Hydrotherapy
-
Air Compression Therapy
-
Phototherapy
-
Traction Table
-
Magnetic Therapy
-
CPM
-
Shock Wave and Ultrasound Therapy
-
Massage Therapy
-
Treatment Table and Tilt Table
-
Microwave and Shortwave Therapy
Hyperoxia and Hypoxia Training System XY-GDY-I
Service: ODM & OEM Service
Quality Certification: CCC
Power Supply Mode: Plug-in
Size: 530mm*610mm*1250mm
Rated Frequency: 50Hz
After-sales Service: Online Technical Support
XY-GDY-I enters the air compressor through pre-filtration. The air compressor applies pressure to the air, which then goes through processes such as drying, filtration, and sterilization. After passing through a special diaphragm, oxygen and nitrogen are split out. According to the control logic of the valve, the oxygen and nitrogen that come out are propored to a certain value to obtain the required low-oxygen or high-oxygen value. Through the gas pipeline and the breathing mask, it acts on the human body.
Advantages
1. Training modes: Hyperoxia mode, hypooxia mode, high and low oxygen mode, normal mode.
2. Oxygen concentration range: Adjustable from 9% to 36%, with a step of 1%. The allowable deviation between the target value and the actual value does not exceed 1%. Among them, the high oxygen concentration is adjustable from 25% to 36%, the low oxygen concentration from 9% to 16%, and the normal mode oxygen concentration from 17% to 24%.
3. Fault Prompt: The equipment conducts real-time monitoring of oxygen concentration (8%-37%), pulse rate (40bpm-200bpm), pressure inside the breathing duct (96kpa-116kpa), and output pressure of the air compressor (160kpa-680kpa). If the values exceed the set range, a prompt will be given.
4. Blood oxygen saturation protection: The blood oxygen protection value is set within the range of 79%-89%, with a step of 1%. When the actual blood oxygen level of the user is lower than the set value, the user's physical functions are protected. The device actively supplies an oxygen concentration of 36%, and at the same time, the screen prompts that oxygen injection is in progress. The training continues only after the user's blood oxygen level returns to 95%.
5. Anti-suffocation: When the equipment training is completed or there is an unexpected power outage and the user fails to remove the oxygen mask in time, the breathing pipe of the equipment is equipped with a one-way air intake valve, allowing the user to breathe normally.
6. User Management: Establish no less than 500 users and store no less than 20,000 training report files for different users.
7. Report export function: After the training is completed, the report can be exported at any time, which is convenient for recording and comparison.
8. Audio prompt: During the training process, the LCD screen displays the training status of the working mode in real time and detects the user's blood oxygen value. When the blood oxygen value is lower than the set value, an audio reminder is given and the LCD screen displays it synchronously until the user's blood oxygen value returns to 95%, the oxygen injection is completed, and the display on the LCD screen disappears. Audio reminders are given at the beginning/end of the training.
9. During the training process, real-time display of oxygen concentration, blood oxygen saturation, pulse rate and respiratory rate is provided.
10.Screen size: 12.1-inch LCD touch screen.
Scope of Application
Suitable for sports training, gym, fitness exercise, beauty salon, plateau adaptation, cardiopulmonary rehabilitation center, health preservation and care.
Contraindications
1. Severe heart, brain and lung diseases or extreme weakness.
2. Patients with bleeding tendency and blood diseases.
3. Patients with severe local skin damage and skin diseases.
4. Patients with infectious diseases, osteoarthritis tuberculosis,osteomyelitis, bone tumors, severe osteoporosis, spinal injury or with spinal cord symptoms.
5, pregnant women more than three months, excessive hunger and drunk state, serious hypertension patients, etc.
6, patients with mild hypertension should not use for too long each time.
Product Parameters
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
|||
|
|
Online Inquiry
Related Products
Contact Us
Contact: Sunnyou
WhatsApp:+86 16668393333
Mob: 0086-16668393333
Email: info@sunnyou.com
Add: Middle Section of Diku Road, Neihuang County, Anyang City, Henan Province, 456300, China
产品链接跳转(禁止删除)
CopyRight © 2020 Xiangyu Medical Co., Ltd 豫ICP备12018840号 Powered by 300.cn Qualification Certificate of Internet Drug Information Service (Henan) - Business 2019-0006
CopyRight © 2020 Xiangyu Medical Co., Ltd