+
  • JDSW-VII.jpg

EMG Biofeedback Stimulation System XY-K-JDSW-VII


Modle Number: XY-K-JDSW-IV Service: ODM & OEM Service Application: Rehab Center & Hospital & Home Display Mode: 24-inch Computer Display Output Channel: Four Channels Sampling Frequency: 16k SPS After-sales Service: Onsite Training
GET PRICE

Electrical signals from the patient's body surface or pelvic floor are collected, evaluated, analyzed, and biofeedback is trained, and electrical stimulation is applied to the patient's muscles to help restore the patient's surface or pelvic floor muscle dysfunction.

 

Software Performance
Universal Function
1.1 EMG biofeedback training has a comprehensive EMG biofeedback training system integrating rapid screening, standard screening, low back pain assessment, neuromuscular electrical stimulation, electromyography-triggered electrical stimulation, biofeedback training, multimedia games, and mirror stimulation;
1.2 For rectum, vagina, and low back, provide rapid screening, standard screening, sEMG assessment for low back pain, sensitivity, and automatic adjustment of scanning speed according to different scenarios;
1.3 Built-in no less than 25 fixed prescriptions;
1.4 The four channels are independent of each other, which can support multiple people to treat at the same time, and can adjust the stimulation intensity independently or synchronously without interfering with each other;
1.5 There are three waveforms, different waveforms are selected for different diseases to enhance the effect and reduce tolerance;
1.6 Reserve data interface, support HIS system docking, and synchronize with hospital patient information, plans, and reports;
1.7 Provide combined protocol function, multiple schemes can preset the treatment sequence, no need to intervene in the middle, reduce the doctor's workload;
1.8 With the function of custom prescription, therapists can independently design and edit the prescription template according to actual needs, and store it in the database, and there is no upper limit on the number of customizations.
1.9 Built-in multimedia biofeedback training includes strength training, endurance training, precision training, coordination training, music relaxation, breathing relaxation, game relaxation, and the training interface can view dynamic muscle potential in real time. Multimedia scene animation treatment plan to improve the interest and compliance of the treatment process. Patients can intuitively see the muscle potential of tone-decreasing and muscle strength gaining, and have training scores, allowing patients to independently evaluate rehabilitation treatment.
1.10 During treatment, there is a schematic diagram of the treatment site and a schematic diagram of the electrode patch, with relevant contraindications, and there is no need for medical staff to memorize too much protocol information. Just follow the system prompts;
1.11 Assessment, treatment, and training have voice prompt functions to guide patients to understand the correct muscle contraction and relaxation movements, and have the function of combination schemes. Set treatment parameters at one time, a complete set of training can be carried out automatically, simple operation, no need for medical staff intervention in the middle, improve the work efficiency of medical staff.
2. Basin Bottom Module
2.1 Rapid screening (screening time only 57 seconds), standard screening (screening time 3 minutes), and detailed reports can be issued, including pre-resting average, variability, rapid systolic maximum, relaxation time, continuous contraction average, variability, relaxation time, and post-resting average, variability. It includes electromyographic trend charts for the entire screening evaluation cycle, and can be filled in by commonly used hand-filled forms such as POP-Q assessment results and manual muscle strength grading. Contains report interpretation references;
2.2 Built-in pelvic floor multimedia biofeedback game training module, focusing on pelvic floor muscle strength, endurance, and relaxation training. Powerful and easy to use; 
2.3 Abdominal muscle participation detection, help detect the degree of participation of the rectus abdominis muscle during pelvic floor muscle training, and correct wrong movements during pelvic floor muscle training;
3. Physical Rehabilitation Module
3.1 Built-in limb multimedia biofeedback game training module, focusing on limb muscle strength (explosiveness), endurance, precision and coordination training;
3.2 Built-in neuromuscular electrical stimulation and trigger electrical stimulation programs for limb rehabilitation, including muscle endurance training, muscle relaxation training, spasticity muscle therapy, dual-part biofeedback training, and muscle synergy;
3.3 Mirror stimulation function, health test drives the affected side to complete the specified limb movements, helping patients build confidence in recovery;

Online Inquiry

* Note: Make sure you fill in the information accurately and keep it open. We will contact you as soon as possible.

Submit